Kidde CO Alarm. With 85 Decibel Alarm. Direct Plug Model (KN-COB-DP-H) 900-0107. 810-1439 REV. Carbon Monoxide. User’s Guide. ATTENTION: Please take a few minutes to thoroughly. Read this manual, which should be saved for future reference and passed on to any subsequent owner. View and Download Kidde Nighthawk user manual online. Nighthawk Carbon Monoxide Alarm pdf manual download. Carbon Monoxide Alarm Kidde KN-COB-DP-LS User Manual. Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline. Kidde Smoke Alarm KN-COB-DP-LS User Guide ManualsOnline.com. Kidde night hawk carbon monoxide alarm eBay. View and Download Kidde KN-COB-DP-LS user manual online. Kidde Carbon Monoxide Alarm User's Guide. KN-COB-DP-LS Carbon Monoxide Alarm pdf manual download. Nighthawk Carbon Monoxide Alarm AC Powered, Plug-In with Battery Backup. Part Number 900-0235. Model KN-COB-DP-LS. The Nighthawk 900-0235 AC Powered, Plug-In carbon monoxide alarm with battery backup is an easy to install unit that provides reliable protection against the dangers of carbon monoxide. Nighthawk Carbon Monoxide Alarm AC Powered, Plug-in with Battery Backup. Part Number 900-0235 Model KN-COB-DP-LS. 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.kidde.com. Architectural and Engineering Specifications. The carbon monoxide alarm shall be Kidde Model KN-COB-DP-LS (part number 900-0235) or approved equal.
Advertising
Nighthawk Carbon Monoxide Alarm
AC Powered, Plug-in with Battery Backup
AC Powered, Plug-in with Battery Backup
Part Number 900-0235
Model KN-COB-DP-LS
Model KN-COB-DP-LS
1016 Corporate Park Drive
Mebane NC 27302
1-800-880-6788
www.kidde.com
Mebane NC 27302
1-800-880-6788
www.kidde.com
Architectural and Engineering
Specifications
Specifications
The carbon monoxide alarm shall be Kidde Model KN-COB-DP-
LS (part number 900-0235) or approved equal. It shall be powered
by a 120VAC, 60 Hz source, along with a 9V battery backup.
by a 120VAC, 60 Hz source, along with a 9V battery backup.
The temperature operating range shall be between 40°F and
100°F (4°C and 38°C) and the humidity operating range shall be
5%-95% relative humidity.
5%-95% relative humidity.
The CO sensor shall be of a fuel cell design and shall meet the
sensitivity requirements of Underwriters Laboratories UL2034
Single and Multiple Station Carbon Monoxide Alarms.
Single and Multiple Station Carbon Monoxide Alarms.
The alarm shall include an integral plug that can be installed
in any electrical outlet following the UL/NFPA/Manufacturer’s
recommended guidelines. The unit shall have a green LED that will
illuminate continuously and indicate that the CO alarm is receiving
power and the alarm circuit is functioning.
recommended guidelines. The unit shall have a green LED that will
illuminate continuously and indicate that the CO alarm is receiving
power and the alarm circuit is functioning.
The alarm shall include a test/reset button. If pressed and re-
leased during normal operation, it shall electronically simulate the
presence of CO and cause the unit to go into alarm. This sequence
tests the unit’s electronics to ensure proper operation. If pressed
during alarm mode, the unit will be silenced and will begin moni-
toring CO levels again.
presence of CO and cause the unit to go into alarm. This sequence
tests the unit’s electronics to ensure proper operation. If pressed
during alarm mode, the unit will be silenced and will begin moni-
toring CO levels again.
The alarm shall include Tamper Resist Feature. If activated, unit
shall go into constant alarm mode until the unit is replaced into
the wall socket or the battery is removed.
the wall socket or the battery is removed.
In accordance with UL 2034, the CO sensor will not alarm to
levels of CO below 30 ppm and will alarm in the following time
range when exposed to the corresponding levels of CO.
range when exposed to the corresponding levels of CO.
70 ppm CO concentration 60 – 240 minutes
150 ppm CO concentration 10 – 50 minutes
400 ppm CO concentration 4 – 15 minutes
150 ppm CO concentration 10 – 50 minutes
400 ppm CO concentration 4 – 15 minutes
The alarm shall include a piezoelectric horn that is rated at 85
decibels at 10 feet. When the unit detects carbon monoxide, the
alarm pattern will be four (4) short beeps – followed by five (5)
seconds of silence – followed by four (4) short beeps.
alarm pattern will be four (4) short beeps – followed by five (5)
seconds of silence – followed by four (4) short beeps.
The unit shall be listed to UL 2034. It shall also include a
7-year manufacturer’s limited warranty.
Technical Specifications
Part Number:
900-0235
Model:
KN-COB-DP-LS
Power Source:
120VAC, 60HZ, 60mA max
9V battery back-up
Sensor:
Electrochemical
Audio Alarm:
85dB at 10ft
Temperature Range:
40˚F (4˚C) to 100˚F (38˚C)
Humidity Range:
10%-95% relative humidity (RH)
Size:
3.0” x 5.6” x 1.5”
Weight:
.62 lbs with battery
Interconnects:
No
Warranty:
7 year limited
Ordering Information
21007308 UPC: 0-47871-07308-5, 21007336 UPC: 0-47871-07336-8, 21007329 UPC: 0-47871-07329-0
*Based on accuracy claims of major manufacturers
**Not for sale by individual unit
Distributed by:
KL-900-0235 sheet
rev. 01-2009
Part
Dimensions
Case/
Skid
Number
I 2 of 5
Pack Quantity
(w x d x h inches)
Weight
Skid
Weight
900-0235**
N/A
Individual (Clam)
7.5 x 2 x 11
1.54 lbs.
N/A
N/A
900-0235**
N/A
Individual (Box)
3.44 x 2.38 x 6
1.54 lbs.
N/A
N/A
21007308
100-47871-07308-2
Cutcase (4 units) Clam
7.94 x 11.88 x 11.50 6.16 lbs.
60
369
21007336
100-47871-07336-5
Cutcase (8 units) Clam
7.94 x 21.63 x 11.5
12.32 lbs.
36
443
21007329
100-47871-07329-7
Cutcase (6 units) Gift Box
7.5 x 8 x 6.5
9.24 lbs.
36
324
Kidde Nighthawk Kn-cob-dp-ls User Manual 2017
Advertising
Kidde Nighthawk Manual Kn-cob-dp-ls-ca
Popular Brands
Popular manuals